epoxyharsisolatie
-
Middelgrote Voltageisolatie
-
De Isolatie van de hoogspannings Epoxyhars
-
Vacuümvermogenschakelaar
-
Epoxyharsring
-
Elektromechanismecomponenten
-
gegoten harstransformator
-
Aardingsschakelaar
-
Koper Elektrocontacten
-
De hoogspanning maakt Schakelaar los
-
De Remhaak van de zinkoxidebliksem
-
Industriële Kabelbanden
-
Elektrobuis Plastic Pijp
-
Hoogspanningsindicatoren
-
gevormde gevalstroomonderbreker
-
de schakelaar van de ladingsbreker
-
De Transformator van de machtsdistributie
-
StephanQiuPu is een grote stroomfabriek. wij stellen zeer u tevreden. met u opnieuw zal samenwerken!
Rubber Tower Type electrical switchgear components Seal Ring

Contacteer me voor vrije steekproeven en coupons.
whatsapp:0086 18588475571
WeChat: 0086 18588475571
Skype: sales10@aixton.com
Als u om het even welke zorg hebt, verstrekken wij de online-Help van 24 uur.
xMaterial | Rubber | Size | 35-110mm |
---|---|---|---|
Type | Tower | Clolor | Black |
Markeren | Rubber electrical switchgear components,Tower electrical switchgear components,electrical switchgear Seal Ring |
Rubber Tower Type Seal Ring for Switchgears
Middle cabinet, all known as metal armor in the case of a shift switch equipment. It is a high voltage distribution unit with a maximum operating voltage of 3.6 / 7.2 / 12kV and is an indoor distribution unit of a three-phase AC 50 Hz single bus segment system or a double bus segment system. It is used to receive and match the network electricity of 3.6-12kV, and to control, protect, monitor and measure the electric circuit. Medium type switchgear is mainly used for power plant, small and medium power generator, power substation of power system, power supply, power distribution of industrial and mining enterprises, and starting of large high voltage motor.
Medium Cabinet full name is the Armoured Installed Switchgear, which moves the medium metal switch with a three-tier structure, with a bus and dashboard(isolated from each other), a circuit breaker room in the middle and a cable room in the lower. Because the circuit breaker is in the middle layer, so it is called the armor type to move the type of metal closed switch equipment, short for the cabinet.
Item | Technical data | ||||||||||||
Rated voltage (KV) | 3.6 | 7.2 | 12 | 24 | 40.5 | ||||||||
Rated frequency(Hz) | 50 | ||||||||||||
Insulator(capacity) | insulating | Frequency withstand voltage 5 min (KV) | 25 | 32 | 42 | 68 | 100 | ||||||
Frequency withstand voltage 1 min (V) | 2000 | ||||||||||||
Lighting impulse withstand voltage (KV) | 40 | 60 | 75 | 125 | 185 | ||||||||
Local discharge (pc) | |||||||||||||
Dispute bend (N) | |||||||||||||